Home ProductsReactive Load Bank

440 V 4375 KVA Reactive Load Bank Ventilation Inspection With Power Factor 0.8

Good quality Portable Load Bank for sales
Good quality Portable Load Bank for sales
We are highly appreciating the neat finishing and will organized system. To be honest with you,as I am in power generation since more than 30 years, your load bank is the best I ever see.It is perfect. Thank you and thank everybody who participated in design manufacturind packaging and handling these banks.

—— Ghalib Zayed

Pls contact Mr.Dong Thai topromote and sell your loadbank. I told Mr.Dong Thai that we are happy with KX Loadbank and also happy with your services

—— Tuong

I'm Online Chat Now

440 V 4375 KVA Reactive Load Bank Ventilation Inspection With Power Factor 0.8

China 440 V 4375 KVA Reactive Load Bank Ventilation Inspection With Power Factor 0.8 supplier
440 V 4375 KVA Reactive Load Bank Ventilation Inspection With Power Factor 0.8 supplier 440 V 4375 KVA Reactive Load Bank Ventilation Inspection With Power Factor 0.8 supplier

Large Image :  440 V 4375 KVA Reactive Load Bank Ventilation Inspection With Power Factor 0.8

Product Details:

Place of Origin: China
Brand Name: KaiXiang
Certification: ISO9001-2008
Model Number: AC440V-4375KVA

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiable
Packaging Details: Container
Delivery Time: Within 35 working days
Payment Terms: Western Union, L/C, T/T
Supply Ability: 30 Set/Sets per Month
Contact Now
Detailed Product Description
Max Load Power: AC440V-4375KVA Rated Voltage /Frequency: AC440V
Colour: Grey Total Tolerance: ±3%
Communication Interface: RS485、RS232 Rated Power: 4375 KVA

440V 4375KVA Reactive Load Bank In Good Performance And Power Factor 0.8
Introduction

1 System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise.

2 The system is a self-developed device used for electricity load testing by Kaixiang Technology. It perfectly combines the high voltage dry type load module and measurement and control module, precisely test output power and load performance of kinds of generator set.

System mainly consists of resistance load, data collecting, control system, cooling device, etc. The system can test output power and load performance of generator sets.

Applications

(1) Installation: Check installation environment , the machine should be placed in the open, flat, safe environment, the bottom four corners must be flat, sturdy sleepers paving to reduce vibration during operation, and improve the reliability of the ground.

(2) Ventilation inspection: Turn on all the ventilation doors of machine, including the top door and side door, and then fixed. Observe if all vents are normal, whether the foreign body obstruction, whether the surroundings neat and clean, near unit will not hinder ventilation debris, make sure the duct patency.

Technical Specifications

 

System Parameters

Rated Voltage/

Frequency

3phase 4wire, 440VAC/60Hz,400VAC/50Hz
MAX Power (AC440V)

Apparent Power:4375kVA

Resistive:3500kW

Inductive:2625kvar

Steps

(AC440V)

Resistive:

15steps,5,10,10,25,50,100,100,200,200,200,200,400,400,800,800kW

Inductive:

15steps,5,10,10,25,25,50,100,100,100,200,200,200,400,400,800kvar

 

Note:Below 440V, power based on ohm’s law descending.

PF 0.8
Precision (each step) ±5%
Precision (Overall) ±3%
Display Precision 0.5 class
Auxiliary Power 3 phase 400VAC/50Hz
Wiring

Load input——Copper Bar(Star)

Auxiliary Power——Line Bank

Communication RS485
Insulation F
Protection IP54
Working Continuity
Cooling Air cooled,horizontal air intake,vertical air outlet
Container packaging,ladder at the front side, window with mesh
Transport hoist,lifting eye on the top
Container Color Grey (RAL7035)
Dimension 6100mm×2438 mm×2591mm(L×W×H)
Weight Around 18000KG
Environment
Temperature -10℃~+50℃
RH ≤95%
Altitude ≤2500m
Air Pressure 86~106kPa
 
 
Main features
Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably.
New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.

Mature Manufacturing Technology: load element using excellent anti-corrosion materials; waterproof insulation container packaging, suitable for adverse environment such as ocean. Internal layout is reasonable, air channel is clear, rapid heat emission, and satisfy continuous working need.

High Power Load: high load power density, large capacity of single set, parallel running to finish super power testing, and realize tens of megawatts of power loading.

Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensures the reliability of data.

Flexible Control Mode: based on different using habit, several control modes as following can be choose, local panel operation, remote box controlling, and intelligent software.

Intelligent Loading: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency. High Efficiency Data Management: display real-time testing data, generate curves graphs automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.

Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.

440 V 4375 KVA Reactive Load Bank Ventilation Inspection With Power Factor 0.8

 

 

 
 

Contact Details
Hebei Kaixiang Electrical Technology Co., Ltd

Contact Person: Bruce

Send your inquiry directly to us (0 / 3000)