Home ProductsDummy Load Bank

3 Phase 300 KW Portable Resistive Load Bank , 4 Wire AC Electronic Load Bank

Good quality Portable Load Bank for sales
Good quality Portable Load Bank for sales
We are highly appreciating the neat finishing and will organized system. To be honest with you,as I am in power generation since more than 30 years, your load bank is the best I ever see.It is perfect. Thank you and thank everybody who participated in design manufacturind packaging and handling these banks.

—— Ghalib Zayed

Pls contact Mr.Dong Thai topromote and sell your loadbank. I told Mr.Dong Thai that we are happy with KX Loadbank and also happy with your services

—— Tuong

I'm Online Chat Now

3 Phase 300 KW Portable Resistive Load Bank , 4 Wire AC Electronic Load Bank

China 3 Phase 300 KW Portable Resistive Load Bank , 4 Wire AC Electronic Load Bank supplier
3 Phase 300 KW Portable Resistive Load Bank , 4 Wire AC Electronic Load Bank supplier 3 Phase 300 KW Portable Resistive Load Bank , 4 Wire AC Electronic Load Bank supplier

Large Image :  3 Phase 300 KW Portable Resistive Load Bank , 4 Wire AC Electronic Load Bank

Product Details:

Place of Origin: China
Brand Name: Kaixiang
Certification: ISO9001
Model Number: AC415V-300kW

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiable
Packaging Details: Packaged in wooden cases
Delivery Time: Within 30 days
Payment Terms: L/C, T/T
Supply Ability: 80Sets/Month
Contact Now
Detailed Product Description
Model: AC415V-300kW Rated Power: 300kW
Voltage: AC415V PF(Power Factor): 1
Display Precision: 0.5 Class Colour: Grey Or Black

AC415V-300kW Dummy Load Bank In Good Performance And Resistive Inductive

Introduction

AC415V-300kW Dummy Load Bank accurately test output power and load capacity of all kinds of generators, main electrical parameters including the dynamic parameters tested.

It is designed for AC power maintenance,could be used widely in power supply,power station etc.This machine is small , light weight digital table display , easy operation , high intelligence, set the parameters of constant current discharge process can be done automatically

Application

AC415V-300kW Dummy Load Bank can be used in a wide variety of applications , such as

Factory testing of turbines ,Factory testing of engine generator sets,Periodic excercising of

stand-by engine generator setsUps system testing,Battery system testing , Load optimization in prime power applications , To reduce wet stacking problems , 

Technical specification

Technical Parameters
Rating Voltage/Frequency AC 415V/50Hz, 3 phase 4 wire
Max Load Power Resistive Load:300kW
Load Step Resistive Load:10 steps; 1,2,2,5,10,20,20,50,100,100kW
Power Factor 1
Load Tolerance(each step) ±5%
Load Tolerance(overall) ±3%
Control Power Supply Input415VAC 3 phase 50Hz
Wire Connection

Load Power Supply Input——Copper bar (star connection)

Control power supply input——connector bar

Communication Interface RS485, RS232
Insulation Class F
Working Mode Continuous Working
Cooling Forced air cooling,Horizontal inlet air,Horizontal outlet
Transportation Hoisting, there are lifting lug in top of case and wheel castors in bottom
Chassis color Grey (RAL7035)
Dimension About1460mm*1980 mm*1800mm(L*W*H)
Weight Approximately 500kg
Operating Environment Parameter
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Altitude ≤2500 meters
Atmospheric Pressure 86~106kPa
 
Main features

Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.

Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.
Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.
Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.
Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.
Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.

 

3 Phase 300 KW Portable Resistive Load Bank , 4 Wire AC Electronic Load Bank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact Details
Hebei Kaixiang Electrical Technology Co., Ltd

Contact Person: Bruce

Send your inquiry directly to us (0 / 3000)