Home ProductsDummy Load Bank

Intelligent Electronic Dummy Load Bank 3546 KVA Electrical Load Testing Equipment

Good quality Portable Load Bank for sales
Good quality Portable Load Bank for sales
We are highly appreciating the neat finishing and will organized system. To be honest with you,as I am in power generation since more than 30 years, your load bank is the best I ever see.It is perfect. Thank you and thank everybody who participated in design manufacturind packaging and handling these banks.

—— Ghalib Zayed

Pls contact Mr.Dong Thai topromote and sell your loadbank. I told Mr.Dong Thai that we are happy with KX Loadbank and also happy with your services

—— Tuong

I'm Online Chat Now

Intelligent Electronic Dummy Load Bank 3546 KVA Electrical Load Testing Equipment

China Intelligent Electronic Dummy Load Bank 3546 KVA Electrical Load Testing Equipment supplier

Large Image :  Intelligent Electronic Dummy Load Bank 3546 KVA Electrical Load Testing Equipment

Product Details:

Place of Origin: China
Brand Name: Kaixiang
Certification: ISO9001
Model Number: AC480-3546KVA

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiable
Packaging Details: Packaged in container
Delivery Time: Within 30 working days
Payment Terms: Western Union, L/C, T/T
Supply Ability: 40Sets/Month
Contact Now
Detailed Product Description
Model: AC480-3546KVA Rated Power: 3546 KVA
Voltage: AC480V PF(Power Factor): 0.8
Display Precision: 0.5 Class Dimension: 6058mm×2438mm×2896mm(L×W×H)

3546 KVA intelligent dummy load bank for genset ups testing

Introduction

 

Triumph load can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW. Resistive, inductive(reactive),capacitive or combined load banks can be customised for any application. They can be used for testing numerous sets in a workshop environment, or used for on-site commissioning, witness tests and proof trials.Tailor-made load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.

 

Application

 

AC480-3546KVA Dummy Load Bank can be used in a wide variety of applications, such as

Ups system testing,Battery system testing,Load optimization in prime power applications

Factory testing of turbines,Factory testing of engine generator sets,To reduce wet stacking problems

Periodic excercising of stand-by engine generator sets

Technical specification

 

System Parameter
Rating voltage/frequency

480V, 3 phase 3 wire, 60HZ

208V, 3 phase 3 wire, 60HZ

Max Load Power

480V,3phase 3wire, 60HZ, star coupling “Y”

Apparent Power: 3546KVA

Resistive Load: 2836kW

Inductive Load: 2128KVAR

208V,3phase 3wire, 60HZ, delta coupling “△”

Apparent Power: 2000KVA

Resistive Load: 1600kW

Inductive Load: 1200KVAR

Load Resolution

208V,3phase 3wire, 60HZ, delta coupling “△”

Resistive load: 0.1,0.2,0.2,0.5,1,2,2,5,10,10,20,50,100,7*200kW

Inductive load: 0.1,0.2,0.2,0.5,1,2,2,5,10,10,20,50,100,5*200kvar

480V,3phase 3wire, 60HZ, star coupling “Y”

Resistive load: 0.18,0.36,0.36,0.9,1.8,3.6,3.6,9,18,18,36,90,180,7*360kW

Inductive load: 0.18,0.36,0.36,0.9,1.8,3.6,3.6,9,18,18,36,90,180,5*360kvar

Power Factor 0.8(lag)
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 line, 380V/50Hz
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions 6058mm×2438mm×2896mm(L×W×H)
Operating Environment Parameter
Workplace Outdoor
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Alloy Resistor Kaixiang
Data Processing Software Kaixiang
 
Main features
Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.
Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.

Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.

Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.

Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.