Home ProductsReactive Load Bank

Electronic Power Banks 271kVA Reactive Load Bank Grey And Black Color

Good quality Portable Load Bank for sales
Good quality Portable Load Bank for sales
We are highly appreciating the neat finishing and will organized system. To be honest with you,as I am in power generation since more than 30 years, your load bank is the best I ever see.It is perfect. Thank you and thank everybody who participated in design manufacturind packaging and handling these banks.

—— Ghalib Zayed

Pls contact Mr.Dong Thai topromote and sell your loadbank. I told Mr.Dong Thai that we are happy with KX Loadbank and also happy with your services

—— Tuong

I'm Online Chat Now

Electronic Power Banks 271kVA Reactive Load Bank Grey And Black Color

China Electronic Power Banks 271kVA Reactive Load Bank Grey And Black Color supplier
Electronic Power Banks 271kVA Reactive Load Bank Grey And Black Color supplier Electronic Power Banks 271kVA Reactive Load Bank Grey And Black Color supplier

Large Image :  Electronic Power Banks 271kVA Reactive Load Bank Grey And Black Color

Product Details:

Place of Origin: China
Brand Name: KaiXiang
Certification: ISO9001-2008
Model Number: AC415V-271kVA

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiable
Packaging Details: Packed in wooden cases
Delivery Time: Within 30 working days
Payment Terms: Western Union, L/C, T/T
Supply Ability: 50 Set/Sets per Month
Contact Now
Detailed Product Description
Max Load Power: AC415V-271kVA Rated Voltage /Frequency: AC415V
Colour: Grey And Black Total Tolerance: ±3%
Communication Interface: RS485、RS232 Rated Power: AC271kVA

electronic power banks 271kVA inductive load bank for generator testing
Introduction

According to the special requirements of users on site, in the agreement the technical standards of AC415-271kVA-RLC Automatic Load Bank and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.

All the schematic diagrams of this agreement are for reference only please in kind prevail.

Applications

1 System can work with PC software to realize intelligent operation, automatically finish the parameters testing, and create testing data table, curves and reports that can be printed, reduce a lot of manual operation.

2 System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise.

Technical Specifications

Technical Parameter
Rating voltage/frequency 415VAC power 271kVA; 3 phase 4 wire, 50Hz, phase voltage 240VAC
Max Load Power Resistive 31kW; inductive 120kvar; capacitive 120kvar
Load Resolution

Resistive Load: 10 steps, 0.1, 0.2, 0.2, 0.5 1, 2, 2, 5, 10, 10kW

Inductive Load: 9 steps, 1, 2, 2, 5, 10, 10, 20, 20, 50kvar

Capacitive Load: 9 steps, 1, 2, 2, 5, 10, 10, 20, 20, 50kvar

Power Factor ±0.2-1
Load Tolerance (resistive load) ±5%
Load Tolerance (inductive load) ±3%
Display Meter Multiple function meter
Fan Control Power External power 380VAC 3 phase 4 wire, 50Hz, phase voltage 220VAC
Wire Connection

Load bank input——busbar (star coupling ”Y”)

Control power input——terminal block

Communication Interface RS232/ RS485
Insulation F
Way of Working Continuous Working
Cooling Forced air cooling, horizontal inlet air and upwards exhaust cooling
Transportation Hoisting, it has lifting eys in top of case and wheel castors in bottom
Color As customer’s requirements or as our design RAL 7035 gray
Dimensions About 2300*1250*1680mm (L*W*H)
Weight About 1500kgs
Operating Environment Parameter
Ambient Temperature -10℃~+40℃
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Used Place indoor
Brands of Main Components
Contactor Schneider
Fuse DELIXI
MCU INFINEON
Alloy Resistor (self-developing)
Data Processing Software (self-developing)
Main features
High Efficiency Data Management: display real-time testing data, generate curves graphs automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.

Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.

Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably.

New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.

Mature Manufacturing Technology: load element using excellent anti-corrosion materials; waterproof insulation container packaging, suitable for adverse environment such as ocean. Internal layout is reasonable, air channel is clear, rapid heat emission, and satisfy continuous working need.

High Power Load: high load power density, large capacity of single set, parallel running to finish super power testing, and realize tens of megawatts of power loading.

Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensures the reliability of data.

Flexible Control Mode: based on different using habit, several control modes as following can be choose, local panel operation, remote box controlling, and intelligent software.

Intelligent Loading: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency.

High Efficiency Data Management: display real-time testing data, generate curves graphs automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.

Electronic Power Banks 271kVA Reactive Load Bank Grey And Black Color

 

 

 
 

Contact Details
Hebei Kaixiang Electrical Technology Co., Ltd

Contact Person: Bruce

Send your inquiry directly to us (0 / 3000)