Home ProductsDummy Load Bank

Full Manual Operation Resistive Load Bank , Emergency Stop Inductive Load Bank

Good quality Portable Load Bank for sales
Good quality Portable Load Bank for sales
We are highly appreciating the neat finishing and will organized system. To be honest with you,as I am in power generation since more than 30 years, your load bank is the best I ever see.It is perfect. Thank you and thank everybody who participated in design manufacturind packaging and handling these banks.

—— Ghalib Zayed

Pls contact Mr.Dong Thai topromote and sell your loadbank. I told Mr.Dong Thai that we are happy with KX Loadbank and also happy with your services

—— Tuong

I'm Online Chat Now

Full Manual Operation Resistive Load Bank , Emergency Stop Inductive Load Bank

China Full Manual Operation Resistive Load Bank , Emergency Stop Inductive Load Bank supplier
Full Manual Operation Resistive Load Bank , Emergency Stop Inductive Load Bank supplier Full Manual Operation Resistive Load Bank , Emergency Stop Inductive Load Bank supplier

Large Image :  Full Manual Operation Resistive Load Bank , Emergency Stop Inductive Load Bank

Product Details:

Place of Origin: China
Brand Name: Kaixiang
Certification: ISO9001
Model Number: AC480V-600kW

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiable
Packaging Details: Packaged in wooden cases
Delivery Time: Within 30 days
Payment Terms: L/C, T/T
Supply Ability: 50Sets/Month
Contact Now
Detailed Product Description
Model: AC480V-600kW Rated Power: 600kW
Voltage: AC480V PF(Power Factor): 1
Colour: Grey Or Black Ambient Temperature: -10℃~+50℃

AC480V-600kW Dummy Load Bank In Good Performance And Resistive Inductive

Introduction

AC480V-600kW Dummy Load Bank  can accurately test output power and load capacity with all kinds of generators, generator sets for all main electrical parameters including the dynamic parameters tested.

System monitoring and load the cabinets of two parts, with the host computer with the use of intelligent, auto-complete for all the electrical parameters of the generator set special test, while generating charts, graphs and test reports, from full manual operation. Provides a scientific means of detection equipment for the power generators.

Application

AC480v-600kW Dummy Load Bank can be used in a wide variety of applications , such as

Factory testing of turbines ,Factory testing of engine generator sets,Periodic excercising of

stand-by engine generator sets, Ups system testing,Battery system testing , Load optimization in prime power applications , To reduce wet stacking problems , 

Technical specification

Technical Parameters
Rating Voltage/Frequency AC 480V/60Hz, 3 phase 4 wire
Max Load Power Resistive load: 600kW
Load Step Resistive load: 11 steps, 1,2,2,5,10,20,20,50,100,200,200kW
Power Factor 1
Load Tolerance(each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power Supply AC400V/60Hz 3 phase 4 wire
Wire Connection

Load power supply input——Copper bar (star coupling)

Control power supply input——Amphenol connector

Communication Interface RS485,RS232
Insulation F grade
Way of Working Continuous Working
Cooling Forced air cooling,Horizontal inlet air,Upward cooling
Transportation Hoisting, there are lifting lug in top of casing and casters in bottom of load bank
Dimension About 1980mm×1460mm×1800mm(length*width*height)
Weight About 1000kgs
Operating Environment Parameter
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Altitude ≤2500 meters
Atmospheric Pressure 86~106kPa
 
Main features
Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.

Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.

Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.
Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.
Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.
Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.
Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

Full Manual Operation Resistive Load Bank , Emergency Stop Inductive Load Bank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact Details
Hebei Kaixiang Electrical Technology Co., Ltd

Contact Person: Bruce

Send your inquiry directly to us (0 / 3000)