Product Details:
Payment & Shipping Terms:
|
Resistive Load: | 500KW | Load Tolerance: | ±3% |
---|---|---|---|
Control Power: | 380VAC/50Hz, 3 Phase 4 Line | Insulation: | F |
Altitude: | ≤1500 Meter | Color: | Grey |
Low Voltage 500Kw Dummy Load Bank 3 Phase With 60 HZ Frequecy
Product Description
1.AC Load Bank offers the most robust, high-capacity designs in the industry.
2.It is setting the standard with intelligent operator controls, safety indication layouts, adjustable load step resolution, and lightweight designs.
3.AC Load Bank is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems.
Technical Parameter
Rating Voltage/Frequency | 400VAC/50Hz, 3 phase 4 wire, |
Rated Load Power | Resistive load: 500kW |
Installed Capacity | Resistive load: 500kW |
Load Step | 1,2,2,5,10,10,20,50,100,100,200kW |
PF(Power Factor) | 1 |
Load Tolerance (each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power | 380VAC/50Hz, 3 phase 4 wire, |
Wire Connection | Load power supply input——Copper bar (star coupling) |
Insulation | F |
Protection Grade | IP21 |
Way of Working | Continuous Working |
Casing Dimensions and Cooling | about 1550*1250*1680mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling |
Weight | About 750kgs/set |
Transportation | Hoisting, there are lifting lug in top of casing |
Casing Color | Grey(RAL7035) |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Altitude | ≤1500 meter |
Atmospheric Pressure | 86~106kPa |
Contactor | Schneider |
Fuse | DELIXI |
MCU | INFINEON |
Data processing software | Kaixiang(self-developed) |
Alloy Resistance | Kaixiang(self-developed) |
Product Advantage
User could load any power within rated power, can test stable state three-phase voltage, current, active power, apparent power, power factor, frequency, running time of generating set.
Whether load/unload by manual control panel or by PC software control, user can pre-set the power then press the master load button.
Application
Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.
With data processing software, could form curve of current, active power, reactive power, apparent power, power factor, frequency and can be printed.
One-key load/unload: user can load or unload with one key easy to control.
3 line LED multi-function meter display.
Contact Person: Bruce