Home Products3 Phase Load Bank

High Power Resistive 3 Phase Load Bank 50HZ F Insulation For Ship Construction

Good quality Portable Load Bank for sales
Good quality Portable Load Bank for sales
We are highly appreciating the neat finishing and will organized system. To be honest with you,as I am in power generation since more than 30 years, your load bank is the best I ever see.It is perfect. Thank you and thank everybody who participated in design manufacturind packaging and handling these banks.

—— Ghalib Zayed

Pls contact Mr.Dong Thai topromote and sell your loadbank. I told Mr.Dong Thai that we are happy with KX Loadbank and also happy with your services

—— Tuong

I'm Online Chat Now

High Power Resistive 3 Phase Load Bank 50HZ F Insulation For Ship Construction

China High Power Resistive 3 Phase Load Bank 50HZ F Insulation For Ship Construction supplier
High Power Resistive 3 Phase Load Bank 50HZ F Insulation For Ship Construction supplier High Power Resistive 3 Phase Load Bank 50HZ F Insulation For Ship Construction supplier

Large Image :  High Power Resistive 3 Phase Load Bank 50HZ F Insulation For Ship Construction

Product Details:

Place of Origin: China
Brand Name: Kaixiang
Certification: ISO9001
Model Number: AC415-5000kW

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiable
Packaging Details: Container for Load bank
Delivery Time: Within 40 working days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 30 Sets per Month
Contact Now
Detailed Product Description
Rated Voltage: AC415v Duty Cycle: Continuous
Insulation: F Class Frequency: 50HZ
Rated Power: 5000 KW Model: AC415-5000kW

5000 KW 3 Phase Resistive Load Bank For Generator UPS Testing

 

Product description

 

AC415-5000kW Automatic Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator, UPS load test.

 

The system consists of 1 sets of 5000kW Resistive load bank. The resistive power is 5000kW. The System is made up of two parts of measurement and control and load, mainly including the outdoor type dry load, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote controller and PC software and so on.

 

Technical Parameter 

 

System Parameter
Rating voltage/frequency 415V 3 phase 4 line,line voltage: 415V, phase voltage: 240V, 50Hz
Max Load Power Resistive Load: 5000kW
Load Resolution

Resistive Load: 33steps,

1kW,2KW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,

200kW,200kW,200kW,200kW,200kW,200KW,200kW,200kW,200kW,

200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,

200kW,200kW,200kW,200kW,200kW,200kW

Power Factor 1
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External 415V 3 phase 4 line, line voltage: 415V, phase voltage: 240V, 50Hz
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions About 9150mm*2350mm*2591mm(L×W×H)
Operating Environment Parameter
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Alloy Resistor (self-developing)
Data Processing Software (self-developing)
Main features

(1) Communication Mode: using photoelectric isolated RS485 communication serial port connect to PC, and with great anti-interference performance to make system control stable. Through converts like USB or RS232 realize communication protocol conversion.

(2) Load Mode: steady-state load (manual load, preset load and automatic load) and transient state load (instant load and instant unload).

(3) Manual Load: input power and power factor, and load according to the preset value.

(4) Preset Load: input generator related parameters, then choose the preset proportion from 0% 25%, 50%, 75%, 100% or other available order and calculate the power value automatically and realize rapid load.

(5) Automatic Load: set several load stages and duration, then complete the process according this stages automatically. Pause at any time or start to next stage in the load process.

Application 

Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test

High Power Resistive 3 Phase Load Bank 50HZ F Insulation For Ship Construction

Contact Details
Hebei Kaixiang Electrical Technology Co., Ltd

Contact Person: Bruce

Send your inquiry directly to us (0 / 3000)