We are highly appreciating the neat finishing and will organized system. To be honest with you,as I am in power generation since more than 30 years, your load bank is the best I ever see.It is perfect. Thank you and thank everybody who participated in design manufacturind packaging and handling these banks.

—— Ghalib Zayed

Pls contact Mr.Dong Thai topromote and sell your loadbank. I told Mr.Dong Thai that we are happy with KX Loadbank and also happy with your services

—— Tuong

I'm Online Chat Now

Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS

China Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS supplier
Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS supplier Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS supplier

Large Image :  Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS

Product Details:

Place of Origin: HEBEI CHINA
Brand Name: KAIXIANG
Certification: ISO9001
Model Number: 1500KW

Payment & Shipping Terms:

Minimum Order Quantity: ONE SET
Price: negotiable
Packaging Details: WOODEN CASE
Delivery Time: ONE MONTH AFTER GET DEPOSIT
Payment Terms: L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram
Supply Ability: 20 SETS ONE MONTH
Contact Now
Detailed Product Description
Name: Variable Resistive Load Bank Model Number: AC400V-1500KW
Frequency: 50 / 60 HZ Rated Power: 1500 KW
Rated Voltage: 400 VAC Rated Current: Depend
Cooling: Forced Air Cooling CasingColor: Grey (RAL7035) Or As Request

 

AC Variable Resistive 400v 1500kw Resistive Load Bank For Testing Generators UPS
 
Product Description

 

1. Load testing: load power that not beyond the rated power, testing and display stable state 3 phases voltage, current, active power, frequency, working time, etc of generator sets.

2. Load/unload with one key:Either by manual control or software control, user can preset the power, then press load master button. Load bank loaded according to preset power to avoid load fluctuation during the power changing.

3. Control Pattern: user can choose local control and intelligent control.

4. Local Control: There is local control panel with several power steps; user can load/unload by button.


Technical Parameters

 

Rating Voltage/Frequency 400VAC 50Hz/60Hz,3phase 4 wire
Max Load Power Resistive Load: 1500kW
Load Step

Resistive Load:16 steps
1,2,2,5,10,10,20,50,100,100,200,200,200,200,200,200kW

Power Factor 1
Load Tolerance(each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power Supply External 415VAC, 3phase 4wire 50Hz
Wire Connection

Load Power Supply Input——Copper bar (star connection)
Control power supply input——Connector bar

Communication Interface RS232 and RS485
Insulation Class F
Duty Cycle Continuous
Cooling Forced air cooling, horizontal air inlet and air outlet
Transportation Hoisting, there are lifting lug in top of case and wheel castors on the bottom
Chassis color Gray(RAL7035)
Size

Approximately 1900mm*2900mm*2100mm
(Width *Length *Height)

Weight Approximately 2000kg
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Altitude ≤2500meters
Atmospheric Pressure 86~106kPa

 
Product Advantage
 

Communication type: through RS232, RS485

Load mode: manual load or automatic load.

Manual load: input power and power factor.

Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100%, etc preset order to make automatic load testing.


Application
 

UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment

Generators installed in the field must be periodically tested and exercised to ensure that it will operate as intended when a power outage actually occurs. Service groups use load banks to apply a load that mimics the load of the facility the generator is protecting. Any problems with the generator can then be identified and rectified in a non-critical environment.

 

Forced Air Cooling Variable Resistive Load Bank For Testing Generators UPS

 