Home Products3 Phase Load Bank

Blue Resistive Reactive Load Bank F Class With Short Circuit Protection

Good quality Portable Load Bank for sales
Good quality Portable Load Bank for sales
We are highly appreciating the neat finishing and will organized system. To be honest with you,as I am in power generation since more than 30 years, your load bank is the best I ever see.It is perfect. Thank you and thank everybody who participated in design manufacturind packaging and handling these banks.

—— Ghalib Zayed

Pls contact Mr.Dong Thai topromote and sell your loadbank. I told Mr.Dong Thai that we are happy with KX Loadbank and also happy with your services

—— Tuong

I'm Online Chat Now

Blue Resistive Reactive Load Bank F Class With Short Circuit Protection

China Blue Resistive Reactive Load Bank F Class With Short Circuit Protection supplier
Blue Resistive Reactive Load Bank F Class With Short Circuit Protection supplier Blue Resistive Reactive Load Bank F Class With Short Circuit Protection supplier

Large Image :  Blue Resistive Reactive Load Bank F Class With Short Circuit Protection

Product Details:

Place of Origin: China
Brand Name: Kaixiang
Certification: ISO9001
Model Number: AC415V-2500kW

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiable
Packaging Details: Container for Load bank
Delivery Time: Within 30 working days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 40 Sets per Month
Contact Now
Detailed Product Description
Power Factor: 0.8(lag) Ambient Temperature: -10℃~+50℃
Rated Voltage: AC415V Dimensions: 6058mm×2350mm×2591mm(L×W×H)
Insulation: F Class Frequency: 50 HZ

AC415V-2500kW 3 Phase Load Bank With Blue Colour And High Performance

Product description

(1) According to the special requirements of users on site, in the agreement the technical standards of AC415V-2500kvA Resistive Inductive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.

(2) The system consists of 1 sets of 2500KVA Load Bank, The resistive power is 2000kW, the inductive power is 1500KVAR. The system is made up of two parts of measurement & control and load, mainly including the medium voltage dry type AC load bank, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on.

Technical Parameter 

System Parameter
Rating voltage/frequency 415V, 3 phase 4 wire 50Hz
Max Load Power

Apparent Power: 2500KVA

Resistive Load: 2000kW

Inductive Load: 1500KVAR

Load Resolution

Resistive Load: 18 steps, 1,2,2,5,10,10,20,50,100,9*200kW

Inductive Load: 17 steps, 0.75,1,2,2,5,10,10,20,50,100,100,6*200kvar

When input voltage lower than rated voltage, load power change according to Ohm’ law

Power Factor 0.8(lag)
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 line, 415V/50Hz
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions 6058mm×2350mm×2591mm(L×W×H)
Operating Environment Parameter
Workplace Outdoor
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Alloy Resistor Kaixiang
Data Processing Software Kaixiang
 
Product Advantage

Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.

Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.

 Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.

Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

Application 

Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Blue Resistive Reactive Load Bank F Class With Short Circuit Protection

 

Contact Details
Hebei Kaixiang Electrical Technology Co., Ltd

Contact Person: Bruce

Send your inquiry directly to us (0 / 3000)