Home ProductsPortable Load Bank

1250kva 50HZ UPS Generator Test Load Bank Continous Working ISO9001 Standard

Good quality Portable Load Bank for sales
Good quality Portable Load Bank for sales
We are highly appreciating the neat finishing and will organized system. To be honest with you,as I am in power generation since more than 30 years, your load bank is the best I ever see.It is perfect. Thank you and thank everybody who participated in design manufacturind packaging and handling these banks.

—— Ghalib Zayed

Pls contact Mr.Dong Thai topromote and sell your loadbank. I told Mr.Dong Thai that we are happy with KX Loadbank and also happy with your services

—— Tuong

I'm Online Chat Now

1250kva 50HZ UPS Generator Test Load Bank Continous Working ISO9001 Standard

China 1250kva 50HZ UPS Generator Test Load Bank Continous Working ISO9001 Standard supplier

Large Image :  1250kva 50HZ UPS Generator Test Load Bank Continous Working ISO9001 Standard

Product Details:

Place of Origin: China
Brand Name: Kaixiang
Certification: ISO9001
Model Number: AC400V-1250kvA

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiable
Packaging Details: Packing in Wooden cases
Delivery Time: Within 30 working days
Payment Terms: Western Union, L/C, T/T
Supply Ability: 60 sets per month
Contact Now
Detailed Product Description
Model: AC400V-1250KVA Rated Power: 1250KVA
Voltage: 400V Frequency: 50HZ
Power Factor: 0.8 Style: Continous Working

1250kva load bank used in UPS generator test in thailand

 

Introduction

 

AC400V-1250kvA Portable Load Bank consists of 1 sets of 1250KVA Load Bank, The resistive power is 1000kW, the inductive power is 750KVAR. The system is made up of two parts of measurement & control and load, mainly including the medium voltage dry type AC load bank, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on.

 

Applications

 

Kaixiang load banks operate at the actual output voltage of medium voltage generators and therefore do not require large step-down transformers, which reduces the overall package size and installation costs. Kaixiang’s quality system is certified to meet ISO9001:2015 standards. Kaixiang AC load banks certified by CE certificate.Our high capacity load banks are exported to more than 20 countries around the globe in a wide variety of applications such as military ships, offshore platforms, data centre, power stations, generator manufacturers and research institutes.Its customers widely distributed in America, Mexico, Netherlands, Australia, Singapore, Israel, Poland, Saudi Arabia, UAE, Egypt, Indonesia, Malaysia,Vietnam, The Philippines, Cambodia, Sudan etc.

 

Technical specification

System Parameter
Rating voltage/frequency 400V, 3 phase 4 wire 60Hz
Max Load Power

Apparent Power: 1250KVA

Resistive Load: 1000kW

Inductive Load: 750KVAR

Load Resolution

Resistive Load: 13 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW,200kW,200kW, 200kW

Inductive Load: 13 steps

1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 50KVAR, 100KVAR,100KVAR,200KVAR,200KVAR

Power Factor 0.8(lag)
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 line, 400V/50Hz
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions 4000mm×2350mm×2591mm(L×W×H)
Operating Environment Parameter
Workplace Outdoor
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
 
Main features

(1) Real-time Monitor: through software display main parameter value, such as voltage, current, power, power factor, frequency and time.

(2) Data Collection Interval: the minimum steady-state data resolving time is 1 second, and the minimum transient data resolving time is 40μs.

(3) Stable Data Comparisons: the max value and min value of all the parameters in steady-state test are listed in software interface; it is convenient for user to compare.

(4) Data Save and Query: all test data are saved in the software, and according to generator set number easy to fast query in the history test data.

(5) Graphical Display: show real-time or history test data, and support to print curve and graph as follows:

1) Voltage, current, frequency and power curves in real-time; 2) voltage curve;

3) Current curve; 4) power curve; 5) frequency curve; 6) power factor curve;

(6) Test Report: display and support to print reports as follow:

1)Test report of generator set steady-state performance; 2)testing data report