Home ProductsPortable Load Bank

1200kw Power AC Generator Load Bank Testing 50HZ F Class Insulation

Good quality Portable Load Bank for sales
Good quality Portable Load Bank for sales
We are highly appreciating the neat finishing and will organized system. To be honest with you,as I am in power generation since more than 30 years, your load bank is the best I ever see.It is perfect. Thank you and thank everybody who participated in design manufacturind packaging and handling these banks.

—— Ghalib Zayed

Pls contact Mr.Dong Thai topromote and sell your loadbank. I told Mr.Dong Thai that we are happy with KX Loadbank and also happy with your services

—— Tuong

I'm Online Chat Now

1200kw Power AC Generator Load Bank Testing 50HZ F Class Insulation

China 1200kw Power AC Generator Load Bank Testing 50HZ F Class Insulation supplier
1200kw Power AC Generator Load Bank Testing 50HZ F Class Insulation supplier 1200kw Power AC Generator Load Bank Testing 50HZ F Class Insulation supplier

Large Image :  1200kw Power AC Generator Load Bank Testing 50HZ F Class Insulation

Product Details:

Place of Origin: China
Brand Name: Kaixiang
Certification: ISO9001
Model Number: AC400-1200kW

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiable
Packaging Details: Packing in Wooden cases
Delivery Time: Within 35 working days
Payment Terms: Western Union, L/C, T/T
Supply Ability: 70 sets per month
Contact Now
Detailed Product Description
Model: AC400-1200kW Rated Power: 1200kW
Voltage: 400V Colour: Grey And Blue
Frequency: 50HZ Insulation: F Class

generator resistive load bank 1200kw AC Variable Resistive Load Bank brazil

 

Introduction

This system, which is of independent research and development of electricity load test equipment by our technology, combining dry load module with the automatic measurement and control module, can accurately detect all kinds of generator output power and load capacity, full load and overload test.

The system can be used with a computer to realize the intelligent control, automatically completing the special test to all electrical parameters of generating set and generating tables, graphs, and supporting the print, comprehensively from the cumbersome manual operation to provide scientific and efficient detection means for the power generating sets.

All the schematic diagrams of this agreement are for reference only please in kind prevail

Applications

Kaixiang load banks operate at the actual output voltage of medium voltage generators and therefore do not require large step-down transformers, which reduces the overall package size and installation costs. Kaixiang’s quality system is certified to meet ISO9001:2015 standards. Kaixiang AC load banks certified by CE certificate.

Our high capacity load banks are exported to more than 20 countries around the globe in a wide variety of applications such as military ships, offshore platforms, data centre, power stations, generator manufacturers and research institutes.Its customers widely distributed in America, Mexico, Netherlands, Australia, Singapore, Israel, Poland, Saudi Arabia, UAE, Egypt, Indonesia, Malaysia,Vietnam, The Philippines, Cambodia, Sudan etc.

Technical specification

AC400-1200kW Automatic Load Bank
Rating Voltage/Frequency 400VAC, 3 phase 4 wire, wire voltage 400V, phase voltage 230V,50Hz
Rated Load Power Resistive load: 1200kW
Installed Capacity Resistive load: 1200kW
Load Step 1,2,2,5,10,10,20,50,100,200,200,200,200,200kW, min step load: 1kW
PF(Power Factor) 1
Load Tolerance (each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power External 380VAC/50Hz, 3 phase 4 wire, 220V 1-phase
Wire Connection

Load power supply input——Copper bar (star coupling)

Control power supply input——Connector-bar

Insulation F
Duty Cycle Continuous
Cooling Type Force air cooling, horizontal air inlet and horizontal air outlet
Transportation Hoisting, there are lifting lug on top and castors at the bottom of casing
Casing Color Grey(RAL7035)or as required
Dimension About 2600mm*1400mm*1800mm
Weight About 1500kgs
Operating Environment Parameter
Workplace Indoor
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Altitude ≤2500 meter
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Data processing software Kaixiang(self-developed)
Alloy Resistance Kaixiang(self-developed)
 

Main features

 

Local manual control: there is local control panel in load bank, with multi load steps, min load steps 1kW, controlled by buttons.

Remote control: remote controller connected the load bank with control cable.(optional)

Intelligent control: user can control load bank by data processing software of PC to make automatic load/unload, display, record and manager the test data, form curve, graph and can be printed.

  • Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.
  • With data processing software, could form curve of current, active power, reactive power, apparent power, power factor, frequency and can be printed.
  • One-key load/unload: user can load or unload with one key easy to control.
  • 3 line LED multi-function meter display.